Scope of use:
It is specially used for the collection and treatment of flammable and explosive dust (such as flour, short fibers, aluminum powder, aluminum alloy, etc.); it is suitable for large-scale grinding, polishing, cutting, powder metallurgy, food processing, food production, polymer plastics Industrial, synthetic dyes and coatings, pesticide and pharmaceutical manufacturing, and plant fiber textile technology, such as multi-station operations and places where there is a danger of dust explosions.
Features:
1. Industrial explosion-proof fans have the advantages of large air volume, low noise, and stable performance; the cabinet type adopts modular design, and the power, air volume, suction, suction port, and pipe diameter can be customized according to customer needs; explosion-proof electric box, Static conductive material high-efficiency filter, flameless discharge;
2. Design the diameter and number of suction ports according to the customer's on-site working conditions, and calculate the fan power suitable for the working conditions;
3. Built-in pulse dusting system, low noise, pulse cleaning can effectively self-clean the filter to ensure the normal operation of the machine, and the pulse cleaning time interval can be set according to different working conditions;
4. 15 4.8M2 filter area high-precision electrostatic conductive material cartridge filters, the total filtering area can reach 72m2, and the filtering precision can reach 0.3 microns;
5. The built-in air duct can effectively reduce the burden on the filter.
6. The oil-water separator can effectively filter the impurities in the compressed air and ensure the normal operation of the pulse system.
7. The latest design of 2 separate large-capacity dust collection drawers makes it more convenient to dump garbage and can meet the needs of long-term work;
Technical Specifications
|
Unit
|
YSL-550E
|
YSL-750E
|
power
|
KW
|
5.5
|
7.5
|
Voltage
|
V
|
380V/50HZ/60HZ
|
capacity
|
L
|
50
|
50
|
Suction diameter
|
MM
|
150/500
|
150/500
|
Filtration accuracy
|
μm
|
0.1~0.3
|
0.1~0.3
|
number of filters
|
EA
|
15
|
15
|
Filter size (diameter*height)
|
mm
|
200*800
|
200*800
|
total filter area
|
M2
|
72
|
72
|
air flow volume
|
M3/H
|
5000~7000
|
6500~9000
|
noise
|
DB
|
72
|
74
|
Full pressure
|
Kpa
|
-2.4~-1.8
|
-2.7~-2.0
|
Power cord length
|
M
|
8
|
8
|
weight
|
KG
|
--
|
--
|
Air pressure
|
Mpa
|
0.5mpa≤work value≤0.4mpa
|
Size (L*W*H)
|
MM
|
1220*1050*2550mm
|
cleaning method
|
Pulse cleaning
|